1
00:00:00,000 --> 00:00:03,060
Avery: Welcome back to Rad Onc 
Smart Review, Breast Oncology. 

2
00:00:03,440 --> 00:00:07,580
Eden: This is Episode fourteen: 
Workshop: partial breast and 

3
00:00:07,580 --> 00:00:11,123
brachytherapy planning. 
Eden: I want you to imagine that

4
00:00:11,123 --> 00:00:13,915
you are sitting alone in the 
dosimetrist suite. 

5
00:00:13,915 --> 00:00:16,700
You open up a brand-new planning
CT scan. 

6
00:00:16,860 --> 00:00:19,865
Avery: And what you're looking 
for is essentially a ghost. 

7
00:00:19,865 --> 00:00:23,465
The surgeon has already gone in,
the tumor has been excised, and 

8
00:00:23,465 --> 00:00:26,765
now you have to target the 
phantom space it left behind. 

9
00:00:26,765 --> 00:00:30,197
And what is your map? 
Avery: You have a fluid pocket 

10
00:00:30,197 --> 00:00:34,061
called a seroma, and you have a 
handful of tiny surgical clips 

11
00:00:34,061 --> 00:00:36,955
that look like little starburst 
artifacts on your screen. 

12
00:00:36,955 --> 00:00:40,402
That is your entire foundation. 
Avery: A treatment plan built on

13
00:00:40,402 --> 00:00:43,773
that foundation has so many 
places to go wrong, from the 

14
00:00:43,773 --> 00:00:47,445
very first contour you draw all 
the way to your final sign-off. 

15
00:00:47,445 --> 00:00:50,199
So today, we're gonna build one 
partial breast plan. 

16
00:00:50,199 --> 00:00:53,016
Avery: We are going from 
simulation to sign-off, and 

17
00:00:53,016 --> 00:00:55,520
we're gonna build a 
brachytherapy alternative on the

18
00:00:55,520 --> 00:00:58,337
same scan. 
At each step, we are gonna ask 

19
00:00:58,337 --> 00:01:01,780
ourselves: Do we accept, do we 
revise, or do we escalate? 

20
00:01:02,080 --> 00:01:04,834
Eden: But first, two recall 
questions. 

21
00:01:04,834 --> 00:01:08,965
Recall question one: What did 
Fast-Forward test against forty 

22
00:01:08,965 --> 00:01:11,260
gray in fifteen fractions? 
Pause. 

23
00:01:11,720 --> 00:01:14,976
Avery: The Fast-Forward trial 
tested two one-week schedules, 

24
00:01:14,976 --> 00:01:18,634
twenty-seven gray and twenty-six
gray, each delivered in five 

25
00:01:18,634 --> 00:01:21,882
fractions directed to the breast
or chest wall. 

26
00:01:21,882 --> 00:01:24,946
Avery: Twenty-six gray was 
non-inferior for local control 

27
00:01:24,946 --> 00:01:28,776
and as safe for normal tissue 
effects at five years. 

28
00:01:28,776 --> 00:01:32,216
However, the twenty-seven gray 
arm resulted in more normal 

29
00:01:32,216 --> 00:01:35,400
tissue effects. 
Eden: Which brings us to the 

30
00:01:35,400 --> 00:01:39,000
second recall question, focusing
on how we find our target. 

31
00:01:39,000 --> 00:01:42,240
Why is the skin scar not the 
boost target? 

32
00:01:42,240 --> 00:01:44,764
Pause. 
Avery: The skin scar can sit 

33
00:01:44,764 --> 00:01:47,904
centimeters from the cavity. 
On average, it is about four 

34
00:01:47,904 --> 00:01:51,662
centimeters away from the clips,
and it can be up to nine 

35
00:01:51,662 --> 00:01:54,088
centimeters away. 
Avery: The tumor bed is defined 

36
00:01:54,088 --> 00:01:56,780
by the clips, the seroma, and 
the operative note. 

37
00:01:57,020 --> 00:01:59,342
Eden: Let's think about the 
mechanics of the surgery. 

38
00:01:59,342 --> 00:02:01,655
The surgeon doesn't always 
plunge a scalpel through the 

39
00:02:01,655 --> 00:02:04,709
skin directly above the tumor. 
Avery: Right, because they are 

40
00:02:04,709 --> 00:02:06,454
thinking about cosmesis. 
Eden: Exactly. 

41
00:02:06,454 --> 00:02:09,120
They might place the incision to
hide the eventual scar. 

42
00:02:09,400 --> 00:02:12,850
Avery: The position of that 
external scar on the skin is 

43
00:02:12,850 --> 00:02:15,354
practically divorced from the 
location of the internal 

44
00:02:15,354 --> 00:02:16,668
surgical bed. 
Eden: Right. 

45
00:02:16,668 --> 00:02:19,406
So if you draw your target 
volume by highlighting the 

46
00:02:19,406 --> 00:02:22,136
tissue directly underneath the 
scar, you could be missing the 

47
00:02:22,136 --> 00:02:24,320
actual tumor bed by up to nine 
centimeters. 

48
00:02:24,760 --> 00:02:27,980
Avery: That is why the scar is a
red herring. 

49
00:02:27,980 --> 00:02:31,193
We rely on the internal 
landmarks, the seroma fluid, the

50
00:02:31,193 --> 00:02:33,440
titanium clips, and the 
surgeon's operative note. 

51
00:02:33,980 --> 00:02:36,828
Eden: Let's bring back the 
fifty-eight-year-old woman we 

52
00:02:36,828 --> 00:02:39,669
met last time. 
She has chosen external beam 

53
00:02:39,669 --> 00:02:43,072
partial breast treatment. 
Eden: She has a one point six 

54
00:02:43,072 --> 00:02:45,744
centimeter, grade two, estrogen 
receptor positive, HER2 negative

55
00:02:45,744 --> 00:02:48,750
invasive ductal carcinoma of the
left upper outer breast. 

56
00:02:48,750 --> 00:02:52,417
It was removed by a lumpectomy. 
Eden: The surgeon placed clips 

57
00:02:52,417 --> 00:02:55,414
on the cavity walls. 
Pathology confirms she has no 

58
00:02:55,414 --> 00:02:58,411
ink on tumor. 
The closest margin is over two 

59
00:02:58,411 --> 00:03:00,409
millimeters. 
She has negative sentinel lymph 

60
00:03:00,409 --> 00:03:02,740
nodes, and there is no 
lymphovascular invasion. 

61
00:03:02,740 --> 00:03:05,580
Avery: She meets the Astro 
guideline's favorable factors 

62
00:03:05,580 --> 00:03:08,420
and has none of its not 
recommended features. 

63
00:03:08,940 --> 00:03:11,176
Eden: Yeah. 
So she is a good candidate for 

64
00:03:11,176 --> 00:03:14,161
partial breast treatment. 
Avery: We are going to evaluate 

65
00:03:14,161 --> 00:03:16,177
two treatment plans for her 
today. 

66
00:03:16,177 --> 00:03:20,368
Avery: The primary plan is an 
external beam plan, thirty gray 

67
00:03:20,368 --> 00:03:24,177
in five fractions delivered 
every other day using IMRT, and 

68
00:03:24,177 --> 00:03:28,357
we are building this plan to the
Florence trial constraint set. 

69
00:03:28,357 --> 00:03:33,887
Avery: But on that same CT scan,
we are also going to evaluate a 

70
00:03:33,887 --> 00:03:36,257
brachytherapy alternative. 
That alternative plan is 

71
00:03:36,257 --> 00:03:40,207
thirty-four gray in ten twice 
daily fractions built to the 

72
00:03:40,207 --> 00:03:42,180
NSABP B thirty-nine protocol 
set. 

73
00:03:42,520 --> 00:03:46,039
Eden: Which immediately brings 
up a really important question. 

74
00:03:46,039 --> 00:03:50,731
So if I am a busy dosimetrist, 
why not just borrow B 

75
00:03:50,731 --> 00:03:53,859
thirty-nine's external beam 
constraint set for her thirty 

76
00:03:53,859 --> 00:03:57,731
gray in five fraction plan? 
Eden: It's all external beam 

77
00:03:57,731 --> 00:04:01,362
partial breast, right? 
Avery: It is so tempting to just

78
00:04:01,362 --> 00:04:03,198
copy and paste that constraint 
set. 

79
00:04:03,198 --> 00:04:05,945
It feels like a safe, 
established standard, but you 

80
00:04:05,945 --> 00:04:08,340
cannot do it. 
Eden: No, you can't. 

81
00:04:08,780 --> 00:04:12,179
Avery: A constraint set is 
married to its specific dose and

82
00:04:12,179 --> 00:04:14,032
fractionation schedule. 
That B thirty-nine constraint 

83
00:04:14,032 --> 00:04:17,112
set belongs to a schedule of 
thirty-eight point five gray 

84
00:04:17,112 --> 00:04:18,959
delivered in ten twice daily 
fractions. 

85
00:04:19,420 --> 00:04:22,354
Eden: Right. 
And if we look at the Rapid 

86
00:04:22,354 --> 00:04:25,605
trial, which used that schedule 
of thirty-eight point five gray 

87
00:04:25,605 --> 00:04:27,880
in ten fractions, they found 
worse cosmesis. 

88
00:04:28,180 --> 00:04:30,196
Avery: Yeah. 
And because of that worse 

89
00:04:30,196 --> 00:04:32,493
cosmesis, the Astro guideline 
does not recommend that 

90
00:04:32,493 --> 00:04:34,116
schedule. 
Eden: Exactly. 

91
00:04:34,116 --> 00:04:38,043
Her schedule of thirty gray in 
five fractions has its own trial

92
00:04:38,043 --> 00:04:41,640
set, from the Florence trial, 
and that is what we use. 

93
00:04:41,820 --> 00:04:44,933
Avery: And with the Florence 
trial set, we have to be 

94
00:04:44,933 --> 00:04:47,480
careful, because Florence 
published that set in two tiers.

95
00:04:47,480 --> 00:04:49,176
First, you have the optimization
limits. 

96
00:04:49,176 --> 00:04:52,531
Avery: These are the limits you 
plug into your inverse planning 

97
00:04:52,531 --> 00:04:55,572
software to optimize each plan. 
Second, you have the final 

98
00:04:55,572 --> 00:04:58,245
acceptability criteria. 
Eden: However, there is one 

99
00:04:58,245 --> 00:05:01,494
caution when we apply the 
Florence constraints to this 

100
00:05:01,494 --> 00:05:04,020
patient's case. 
The Florence trial excluded any 

101
00:05:04,020 --> 00:05:06,900
patient who had surgical margins
under five millimeters. 

102
00:05:07,500 --> 00:05:10,701
Avery: And if we look back at 
her pathology report, her 

103
00:05:10,701 --> 00:05:13,320
closest margin is recorded 
simply as over two millimeters. 

104
00:05:13,900 --> 00:05:16,360
Eden: Does that mean we can't 
use the Florence constraints? 

105
00:05:16,920 --> 00:05:18,774
Avery: No. 
It just means we have to be 

106
00:05:18,774 --> 00:05:21,097
honest about what we are doing. 
Avery: The Florence constraint 

107
00:05:21,097 --> 00:05:23,545
set acts as our planning 
reference for her chosen 

108
00:05:23,545 --> 00:05:26,808
schedule of thirty gray in five 
fractions, but we are not making

109
00:05:26,808 --> 00:05:29,789
a clinical claim that she would 
have been eligible for that 

110
00:05:29,789 --> 00:05:32,236
trial. 
Eden: Let's move the patient 

111
00:05:32,236 --> 00:05:35,606
into the simulation room. 
She lies supine on a standard 

112
00:05:35,606 --> 00:05:38,631
breast board. 
We take a planning CT that must 

113
00:05:38,631 --> 00:05:41,991
cover the whole breast and both 
lungs in thin slices. 

114
00:05:42,931 --> 00:05:46,479
Avery: Florence set patients up 
just like this, supine on a 

115
00:05:46,479 --> 00:05:49,377
breast board, but with no other 
immobilization and no 

116
00:05:49,377 --> 00:05:51,636
respiratory control. 
Avery: The exact arm position 

117
00:05:51,636 --> 00:05:54,857
and whether an institution 
chooses to add a breath hold, 

118
00:05:54,857 --> 00:05:57,111
well, that's left up to 
institutional practice. 

119
00:05:58,091 --> 00:06:01,163
Eden: Beyond the physical 
positioning and the slice 

120
00:06:01,163 --> 00:06:03,845
thickness, there is an 
overarching factor in 

121
00:06:03,845 --> 00:06:06,371
simulation, timing. 
Avery: Timing is huge. 

122
00:06:06,791 --> 00:06:09,748
Eden: The timing of the 
simulation matters because 

123
00:06:09,748 --> 00:06:12,331
post-surgical change is not 
static, it fades. 

124
00:06:12,991 --> 00:06:15,695
Avery: Immediately after 
surgery, that seroma, the fluid 

125
00:06:15,695 --> 00:06:19,751
left by the lumpectomy, is 
usually plump and easy to see on

126
00:06:19,751 --> 00:06:21,779
a CT. 
Over the weeks following 

127
00:06:21,779 --> 00:06:24,480
surgery, the body starts 
reabsorbing that seroma fluid. 

128
00:06:24,480 --> 00:06:27,879
Avery: The cavity walls begin to
collapse inward, and the whole 

129
00:06:27,879 --> 00:06:31,287
area starts to shrink. 
Eden: Which is why you want to 

130
00:06:31,287 --> 00:06:34,166
simulate the patient while that 
seroma and the surgical clips 

131
00:06:34,166 --> 00:06:36,979
are still clearly visible. 
Eden: If you simulate too late, 

132
00:06:36,979 --> 00:06:40,303
the seroma might be gone, and 
you are left guessing where the 

133
00:06:40,303 --> 00:06:43,277
high-risk bed actually is. 
Avery: And if the cavity changes

134
00:06:43,277 --> 00:06:46,258
size or if the patient's setup 
changes between the day of 

135
00:06:46,258 --> 00:06:48,961
simulation and the first day of 
treatment, you cannot just 

136
00:06:48,961 --> 00:06:50,311
proceed. 
You have to resimulate. 

137
00:06:51,191 --> 00:06:54,985
Eden: Oh, definitely. 
Avery: Since we are running a 

138
00:06:54,985 --> 00:06:58,392
brachytherapy alternative plan 
in parallel, we need to clarify 

139
00:06:58,392 --> 00:07:01,416
some surgical terms that affect 
how we plan. 

140
00:07:01,416 --> 00:07:05,196
The terms open cavity and closed
cavity have very specific 

141
00:07:05,196 --> 00:07:07,529
meanings. 
Avery: They describe how the 

142
00:07:07,529 --> 00:07:09,484
surgeon closed the lumpectomy 
defect. 

143
00:07:09,484 --> 00:07:13,391
They do not describe when the 
brachytherapy catheters go into 

144
00:07:13,391 --> 00:07:15,951
the breast. 
Eden: That's a vital 

145
00:07:15,951 --> 00:07:18,975
distinction. 
Avery: An open cavity means the 

146
00:07:18,975 --> 00:07:22,861
surgeon closed the skin, leaving
the deep surgical defect open to

147
00:07:22,861 --> 00:07:26,391
fill with fluid, and that fluid 
pocket is the seroma. 

148
00:07:27,051 --> 00:07:29,771
Eden: Exactly. 
A closed cavity, on the other 

149
00:07:29,771 --> 00:07:33,851
hand, means the surgeon took the
time to bring the deep tissue 

150
00:07:33,851 --> 00:07:37,591
walls of the defect together. 
It is a full thickness closure, 

151
00:07:37,591 --> 00:07:41,331
so there is no empty space left,
and no seroma forms. 

152
00:07:41,691 --> 00:07:44,499
Avery: Now, how do the 
brachytherapy catheters actually

153
00:07:44,499 --> 00:07:47,301
get into the patient? 
Typically, for a multi-catheter 

154
00:07:47,301 --> 00:07:51,151
implant, they go in through the 
skin some weeks after the 

155
00:07:51,151 --> 00:07:52,635
lumpectomy surgery. 
Eden: Right. 

156
00:07:52,635 --> 00:07:56,165
And the treatment plan is then 
generated on a new CT scan taken

157
00:07:56,165 --> 00:07:57,791
with all those catheters in 
place. 

158
00:07:58,231 --> 00:08:01,891
Avery: And if we are talking 
about a single entry device like

159
00:08:01,891 --> 00:08:04,939
a balloon applicator or a 
strut-based device, that is a 

160
00:08:04,939 --> 00:08:06,979
different process entirely. 
Eden: Yeah. 

161
00:08:06,979 --> 00:08:10,119
That device is inserted through 
a single small incision directly

162
00:08:10,119 --> 00:08:13,887
into the lumpectomy cavity. 
Then we take a CT scan to check 

163
00:08:13,887 --> 00:08:17,018
its exact position and expansion
before we even start planning. 

164
00:08:17,018 --> 00:08:20,427
Eden: Once it is positioned, it 
stays in place for the entire 

165
00:08:20,427 --> 00:08:22,131
course of the twice daily 
treatments. 

166
00:08:22,611 --> 00:08:25,003
Avery: Okay. 
Let's pause right here for our 

167
00:08:25,003 --> 00:08:27,693
first workshop question, putting
you in the driver's seat. 

168
00:08:27,693 --> 00:08:30,673
What do you need from the 
surgeon before you simulate? 

169
00:08:30,673 --> 00:08:32,561
Pause. 
Eden: You need the operative 

170
00:08:32,561 --> 00:08:34,461
note. 
You need to know where the clips

171
00:08:34,461 --> 00:08:36,120
are and why they were placed 
there. 

172
00:08:36,120 --> 00:08:39,342
Eden: You need to know if any 
breast tissue was moved, 

173
00:08:39,342 --> 00:08:42,847
rotated, or advanced to fill the
defect, and you must know the 

174
00:08:42,847 --> 00:08:44,891
pathology margins in every 
direction, superior, inferior, 

175
00:08:44,891 --> 00:08:46,351
medial, lateral, superficial, 
and deep. 

176
00:08:46,886 --> 00:08:50,235
Avery: Now we have the scan, we 
have the op note, and we have to

177
00:08:50,235 --> 00:08:53,067
find the cavity. 
Avery: You have to read the CT 

178
00:08:53,067 --> 00:08:56,157
scan as a combination of three 
things together, the seroma 

179
00:08:56,157 --> 00:08:59,247
fluid, the surgical clips, and 
any changes in the surrounding 

180
00:08:59,247 --> 00:09:01,153
tissue architecture. 
Avery: And you cross-reference 

181
00:09:01,153 --> 00:09:04,046
all three of those things 
against the operative note. 

182
00:09:04,246 --> 00:09:07,110
Eden: The Astro guideline is 
specific about this. 

183
00:09:07,110 --> 00:09:11,406
It instructs us to draw the 
tumor bed around the clips and 

184
00:09:11,406 --> 00:09:14,628
that architectural change. 
In her scan, we are really 

185
00:09:14,628 --> 00:09:17,127
fortunate. 
The scan shows a clearly visible

186
00:09:17,127 --> 00:09:19,838
fluid-filled seroma. 
Eden: We can clearly see the 

187
00:09:19,838 --> 00:09:23,158
clips sitting right at the walls
of that fluid pocket. 

188
00:09:23,158 --> 00:09:26,146
Because of this, her cavity can 
be localized confidently. 

189
00:09:26,566 --> 00:09:29,102
Avery: But let's talk about the 
closed cavity. 

190
00:09:29,102 --> 00:09:32,589
We discussed that a closed 
cavity has no seroma because the

191
00:09:32,589 --> 00:09:34,173
surgeon sutured the walls 
together. 

192
00:09:34,173 --> 00:09:36,069
This makes finding the target 
harder. 

193
00:09:36,069 --> 00:09:38,926
Avery: If there is no fluid 
pocket, what are you targeting? 

194
00:09:39,326 --> 00:09:42,896
Eden: You are targeting the 
surgical scar tissue inside the 

195
00:09:42,896 --> 00:09:44,681
breast. 
The European closed-cavity atlas

196
00:09:44,681 --> 00:09:47,537
provides guidance here. 
It suggests marking the external

197
00:09:47,537 --> 00:09:50,744
skin scar on the CT scan using a
wire. 

198
00:09:50,744 --> 00:09:53,217
Eden: This serves as a general 
directional guide. 

199
00:09:53,217 --> 00:09:57,234
But the atlas stresses that the 
skin scar is not the bed itself.

200
00:09:57,234 --> 00:10:00,964
Eden: The actual bed contour 
takes in the internal scar 

201
00:10:00,964 --> 00:10:03,942
tissue and the architectural 
distortion, together with the 

202
00:10:03,942 --> 00:10:06,486
surgical clips. 
Avery: And what if the surgeon 

203
00:10:06,486 --> 00:10:09,177
didn't leave clips? 
If you have a closed cavity, so 

204
00:10:09,177 --> 00:10:12,405
there is no seroma, and you have
no clips, and you can't 

205
00:10:12,405 --> 00:10:14,826
distinguish any internal scar 
tissue, what do you do? 

206
00:10:15,086 --> 00:10:17,866
Eden: The atlas is clear. 
It says no bed can be drawn. 

207
00:10:18,406 --> 00:10:22,116
Avery: And oncoplastic surgery 
adds a second problem to target 

208
00:10:22,116 --> 00:10:24,886
localization. 
Eden: Oncoplastic surgery is 

209
00:10:24,886 --> 00:10:27,511
essentially combining cancer 
removal with plastic surgery 

210
00:10:27,511 --> 00:10:30,136
techniques. 
Instead of just taking a lump 

211
00:10:30,136 --> 00:10:34,254
out, the surgeon might perform a
breast reduction or a breast 

212
00:10:34,254 --> 00:10:38,406
lift at the same time. 
Eden: They remove the tumor, but

213
00:10:38,406 --> 00:10:41,826
then they mobilize, rotate, and 
rearrange the remaining healthy 

214
00:10:41,826 --> 00:10:44,884
breast tissue. 
Avery: Once that tissue is moved

215
00:10:44,884 --> 00:10:48,760
and rotated, the actual area 
where the tumor used to be may 

216
00:10:48,760 --> 00:10:51,980
not lie under the skin scar 
anymore, or inside whatever 

217
00:10:51,980 --> 00:10:54,066
small seroma forms. 
Eden: Exactly. 

218
00:10:54,366 --> 00:10:57,534
Avery: In an oncoplastic case, 
the clips placed on the cavity 

219
00:10:57,534 --> 00:11:00,979
walls by the surgeon before the 
tissue is moved are your map. 

220
00:11:00,979 --> 00:11:03,979
Avery: The Astro guideline 
states that partial breast 

221
00:11:03,979 --> 00:11:06,976
treatment after oncoplastic 
surgery depends on your ability 

222
00:11:06,976 --> 00:11:11,492
to confidently find the cavity. 
Eden: Which brings us to the 

223
00:11:11,492 --> 00:11:14,159
second workshop question. 
Oncoplastic closure, no clips, 

224
00:11:14,159 --> 00:11:17,966
and the seroma has collapsed. 
Can you plan partial breast 

225
00:11:17,966 --> 00:11:18,726
treatment? 
Pause. 

226
00:11:19,306 --> 00:11:21,784
Avery: No. 
If you cannot confidently find 

227
00:11:21,784 --> 00:11:24,966
the cavity, you cannot draw a 
partial breast target. 

228
00:11:26,106 --> 00:11:28,950
Eden: B thirty-nine required a 
clearly delineated cavity for 

229
00:11:28,950 --> 00:11:30,382
enrollment. 
Eden: The Florence trial 

230
00:11:30,382 --> 00:11:33,442
excluded patients who did not 
have surgical clips left in the 

231
00:11:33,442 --> 00:11:35,944
tumor bed, and brachytherapy 
guidance says the target cannot 

232
00:11:35,944 --> 00:11:39,002
be defined in that situation. 
When you are faced with this, 

233
00:11:39,002 --> 00:11:41,043
you escalate. 
Eden: You offer the patient 

234
00:11:41,043 --> 00:11:42,526
standard whole breast radiation 
instead. 

235
00:11:43,104 --> 00:11:46,785
Avery: Let's assume we can see 
the cavity clearly, like in her 

236
00:11:46,785 --> 00:11:49,233
case. 
Now we move into the geometry of

237
00:11:49,233 --> 00:11:51,650
target construction. 
Avery: Let's start with the 

238
00:11:51,650 --> 00:11:55,260
NSABP B thirty-nine definitions 
as our reference chain for 3D 

239
00:11:55,260 --> 00:11:56,704
conformal external beam 
radiation. 

240
00:11:56,984 --> 00:12:01,222
Eden: The clinical target 
volume, or CTV, is created by 

241
00:12:01,222 --> 00:12:05,029
taking that excision cavity and 
expanding it uniformly by 

242
00:12:05,029 --> 00:12:07,144
fifteen millimeters in all 
directions. 

243
00:12:07,424 --> 00:12:10,079
Avery: If the cavity's near the 
skin, that expansion will push 

244
00:12:10,079 --> 00:12:13,738
right out into the air. 
Eden: Exactly, and that is why 

245
00:12:13,738 --> 00:12:17,010
we have cropping rules. 
In B thirty-nine, this 

246
00:12:17,010 --> 00:12:20,282
fifteen-millimeter CTV expansion
is kept five millimeters away 

247
00:12:20,282 --> 00:12:23,384
from the external skin surface. 
Avery: Why? 

248
00:12:23,864 --> 00:12:26,690
Eden: Because the full 
prescription dose on the skin 

249
00:12:26,690 --> 00:12:29,826
can damage it. 
And the CTV is limited by the 

250
00:12:29,826 --> 00:12:31,704
posterior extent of the breast 
tissue. 

251
00:12:31,924 --> 00:12:34,939
Avery: So that gives us our CTV,
but patients breathe. 

252
00:12:34,939 --> 00:12:37,354
They shift on the table. 
Eden: Right. 

253
00:12:37,354 --> 00:12:40,034
We need the planning target 
volume, or PTV. 

254
00:12:40,034 --> 00:12:44,054
In B thirty-nine, you take that 
CTV and add a uniform ten 

255
00:12:44,054 --> 00:12:47,069
millimeters in all directions. 
This accounts for setup error 

256
00:12:47,069 --> 00:12:49,409
and the breathing motion of the 
chest. 

257
00:12:49,409 --> 00:12:53,128
Eden: This uncropped PTV is a 
large structure, and it is what 

258
00:12:53,128 --> 00:12:56,058
shapes the beam aperture. 
Avery: But wait, if we evaluate 

259
00:12:56,058 --> 00:12:59,394
the dose on that uncropped PTV, 
part of it is in the air outside

260
00:12:59,394 --> 00:13:02,488
the patient, and part of it is 
hitting the skin we just tried 

261
00:13:02,488 --> 00:13:05,034
to protect. 
Eden: Which is why B thirty-nine

262
00:13:05,034 --> 00:13:08,484
created a third structure, the 
PTV eval, or PTV evaluation. 

263
00:13:08,484 --> 00:13:11,924
You take that uncropped PTV, and
you crop it again. 

264
00:13:11,924 --> 00:13:16,005
Eden: You remove any part that 
extends outside the breast, and 

265
00:13:16,005 --> 00:13:19,710
you carve away the first five 
millimeters under the skin. 

266
00:13:19,710 --> 00:13:23,410
B thirty-nine checks its dose 
volume limits on this cropped 

267
00:13:23,410 --> 00:13:26,384
PTV eval structure. 
Eden: But the radiation beams 

268
00:13:26,384 --> 00:13:29,732
themselves are still shaped 
based on the larger uncropped 

269
00:13:29,732 --> 00:13:31,164
PTV. 
Avery: Got it. 

270
00:13:31,164 --> 00:13:34,942
Eden: But remember, our patient 
is getting her thirty gray in 

271
00:13:34,942 --> 00:13:37,686
five fractions using the 
Florence protocol, and Florence 

272
00:13:37,686 --> 00:13:41,459
had its own target definitions. 
In Florence, the CTV is smaller.

273
00:13:41,459 --> 00:13:45,156
Eden: It is defined as the 
surgical clips plus a uniform 

274
00:13:45,156 --> 00:13:47,508
expansion of one centimeter, not
fifteen millimeters. 

275
00:13:47,508 --> 00:13:50,738
Eden: It is kept three 
millimeters inside the skin, not

276
00:13:50,738 --> 00:13:54,282
five, and three millimeters away
from the lung and chest wall 

277
00:13:54,282 --> 00:13:57,374
interface. 
Avery: Then to get the PTV in 

278
00:13:57,374 --> 00:13:59,677
Florence, you add another one 
centimeter margin. 

279
00:13:59,677 --> 00:14:02,967
This PTV is also kept three 
millimeters inside the skin. 

280
00:14:02,967 --> 00:14:06,257
Florence allowed this PTV to 
extend up to four millimeters 

281
00:14:06,257 --> 00:14:09,898
into the lung. 
Eden: Florence did not define a 

282
00:14:09,898 --> 00:14:12,364
separate PTV eval structure like
B thirty-nine did. 

283
00:14:12,364 --> 00:14:15,752
So the cropped structure is 
simply called the PTV, and that 

284
00:14:15,752 --> 00:14:18,754
is what you evaluate. 
Avery: The Astro guideline gives

285
00:14:18,754 --> 00:14:21,138
us a range rather than a single 
number. 

286
00:14:21,138 --> 00:14:24,711
Astro suggests a CTV margin 
ranging from one to one and a 

287
00:14:24,711 --> 00:14:26,790
half centimeters away from the 
tumor bed. 

288
00:14:26,790 --> 00:14:29,805
Avery: A one centimeter margin 
is considered appropriate if 

289
00:14:29,805 --> 00:14:32,820
your pathology report shows 
clear surgical margins of two 

290
00:14:32,820 --> 00:14:36,160
millimeters or more. 
Once you have that CTV, you then

291
00:14:36,160 --> 00:14:40,566
add a one centimeter PTV margin.
Eden: So for our patient, her 

292
00:14:40,566 --> 00:14:42,585
surgical margins are over two 
millimeters. 

293
00:14:42,585 --> 00:14:45,945
Therefore, a one centimeter CTV 
expansion fits within both the 

294
00:14:45,945 --> 00:14:47,961
Florence protocol and the Astro 
guideline. 

295
00:14:47,961 --> 00:14:51,275
Eden: But do not mix the Astro 
guideline's skin cropping rules 

296
00:14:51,275 --> 00:14:53,984
with the Florence target 
expansions on the same plan. 

297
00:14:54,644 --> 00:14:57,324
Avery: Right. 
If you are evaluating a plan 

298
00:14:57,324 --> 00:15:00,004
against the Florence 
constraints, you must build the 

299
00:15:00,004 --> 00:15:02,349
targets using the Florence 
definitions, three millimeter 

300
00:15:02,349 --> 00:15:05,699
skin crop and all. 
You must use one complete rule 

301
00:15:05,699 --> 00:15:08,938
book per plan. 
Eden: Our alternative plan on 

302
00:15:08,938 --> 00:15:12,061
the same scan is the B 
thirty-nine brachytherapy arm. 

303
00:15:12,061 --> 00:15:15,878
If we are doing a multicatheter 
implant, the target is the 

304
00:15:15,878 --> 00:15:18,303
lumpectomy cavity plus a fifteen
millimeter expansion. 

305
00:15:18,823 --> 00:15:22,200
Avery: For a single entry 
device, the target is a ten 

306
00:15:22,200 --> 00:15:24,656
millimeter rim of tissue 
expanding outward from the 

307
00:15:24,656 --> 00:15:27,704
surface of the device itself. 
Avery: You then subtract the 

308
00:15:27,704 --> 00:15:31,037
actual volume of the device, so 
you are only evaluating the 

309
00:15:31,037 --> 00:15:34,956
breast tissue rim. 
Eden: And for both of those B 

310
00:15:34,956 --> 00:15:36,987
thirty-nine techniques, 
multicatheter and single entry, 

311
00:15:36,987 --> 00:15:40,705
the target volume is kept five 
millimeters under the skin for 

312
00:15:40,705 --> 00:15:42,717
evaluation. 
Avery: The European 

313
00:15:42,717 --> 00:15:45,581
brachytherapy atlases use a 
different formula for target 

314
00:15:45,581 --> 00:15:48,087
construction. 
They take a base margin of 

315
00:15:48,087 --> 00:15:50,951
twenty millimeters, and then 
they subtract whatever the 

316
00:15:50,951 --> 00:15:53,773
surgical margin was. 
Eden: For example, if the 

317
00:15:53,773 --> 00:15:57,183
surgeon left a ten millimeter 
rim of healthy tissue around the

318
00:15:57,183 --> 00:16:00,891
tumor, the European rule says 
you only need to add another ten

319
00:16:00,891 --> 00:16:03,363
millimeters of radiation margin,
that's twenty minus ten. 

320
00:16:04,083 --> 00:16:07,071
Avery: However, the European 
closed cavity atlas and the 

321
00:16:07,071 --> 00:16:09,727
Astro table place a floor on 
this calculation. 

322
00:16:09,727 --> 00:16:13,047
They do not let that final 
margin fall below ten 

323
00:16:13,047 --> 00:16:16,032
millimeters, regardless of how 
wide the surgical margin was. 

324
00:16:16,032 --> 00:16:19,227
Avery: The open cavity atlas 
doesn't set that floor. 

325
00:16:19,227 --> 00:16:22,063
Again, use one complete rule 
book per plan. 

326
00:16:22,063 --> 00:16:24,895
Don't mix European target 
calculations with B thirty-nine 

327
00:16:24,895 --> 00:16:27,843
dose constraints. 
Eden: Why do these expansions 

328
00:16:27,843 --> 00:16:30,819
differ so much between external 
beam and brachytherapy? 

329
00:16:30,819 --> 00:16:34,911
Why does B thirty-nine external 
beam add a ten millimeter PTV 

330
00:16:34,911 --> 00:16:38,252
margin, while brachytherapy adds
zero millimeters for setup and 

331
00:16:38,252 --> 00:16:40,673
breathing? 
Avery: Think about where the 

332
00:16:40,673 --> 00:16:43,679
radiation source is located. 
With external beam, the linear 

333
00:16:43,679 --> 00:16:45,345
accelerator is outside the 
patient. 

334
00:16:45,345 --> 00:16:48,342
Because the patient is 
breathing, the breast is moving.

335
00:16:48,342 --> 00:16:51,330
Avery: You need a one centimeter
margin to ensure the beam hits 

336
00:16:51,330 --> 00:16:54,261
the tumor bed as it moves. 
Eden: Exactly. 

337
00:16:54,261 --> 00:16:57,125
But with brachytherapy, the 
radioactive source is placed 

338
00:16:57,125 --> 00:17:00,347
inside the catheters or the 
balloon, which are embedded 

339
00:17:00,347 --> 00:17:03,399
inside the breast tissue. 
Eden: When the patient breathes 

340
00:17:03,399 --> 00:17:06,630
and the breast moves, the 
radiation source moves in sync 

341
00:17:06,630 --> 00:17:09,214
with the target. 
Therefore, no setup or breathing

342
00:17:09,214 --> 00:17:12,950
margin is needed. 
Avery: So you have to use the 

343
00:17:12,950 --> 00:17:15,652
exact target definitions of the 
protocol whose dosimetric limits

344
00:17:15,652 --> 00:17:18,051
you're quoting. 
For example, let's look at the 

345
00:17:18,051 --> 00:17:20,102
uninvolved breast. 
Avery: The Florence protocol has

346
00:17:20,102 --> 00:17:23,582
a limit on the dose to the 
breast tissue that doesn't have 

347
00:17:23,582 --> 00:17:25,612
cancer in it. 
Florence defines this uninvolved

348
00:17:25,612 --> 00:17:28,502
breast as the entire ipsilateral
breast volume minus the PTV. 

349
00:17:29,023 --> 00:17:31,615
Eden: And that Florence 
definition of the uninvolved 

350
00:17:31,615 --> 00:17:35,503
breast is not the same thing as 
the B thirty-nine whole breast 

351
00:17:35,503 --> 00:17:37,443
reference volume, which is 
calculated differently. 

352
00:17:38,009 --> 00:17:42,145
Avery: So let's shift our focus 
to the delivery technique for 

353
00:17:42,145 --> 00:17:45,149
the external beam plan. 
Florence used IMRT, intensity 

354
00:17:45,149 --> 00:17:47,774
modulated radiation therapy, 
with coplanar six megavolt 

355
00:17:47,774 --> 00:17:50,089
fields. 
Eden: And they angled the fields

356
00:17:50,089 --> 00:17:52,980
so that the radiation steered 
clear of the opposite healthy 

357
00:17:52,980 --> 00:17:56,393
breast. 
Avery: B thirty-nine, on the 

358
00:17:56,393 --> 00:17:58,953
other hand, relied on 3D 
conformal radiation therapy. 

359
00:17:58,953 --> 00:18:01,833
They used non-coplanar beams, 
meaning the angles came from 

360
00:18:01,833 --> 00:18:04,778
different planes in 3D space. 
Avery: They accepted no plan 

361
00:18:04,778 --> 00:18:08,005
that featured a radiation beam 
aimed at the heart, the lung or 

362
00:18:08,005 --> 00:18:11,299
the other breast. 
Eden: Now, our patient is 

363
00:18:11,299 --> 00:18:13,735
getting thirty gray in five 
fractions. 

364
00:18:13,735 --> 00:18:16,979
Any five-fraction partial breast
treatment should have daily 

365
00:18:16,979 --> 00:18:19,327
image guidance. 
Avery: The Astro guideline 

366
00:18:19,327 --> 00:18:23,035
advises this daily imaging, and 
the same for any plan where the 

367
00:18:23,035 --> 00:18:24,889
PTV margins are under one 
centimeter. 

368
00:18:25,149 --> 00:18:27,709
Eden: What about the spacing of 
those fractions? 

369
00:18:27,709 --> 00:18:30,269
Our patient is scheduled for 
every other day. 

370
00:18:30,269 --> 00:18:32,829
Why did the Florence 
investigators choose every other

371
00:18:32,829 --> 00:18:35,069
day instead of treating Monday 
through Friday? 

372
00:18:35,449 --> 00:18:38,969
Avery: Well, they chose it out 
of caution about normal tissue 

373
00:18:38,969 --> 00:18:41,439
toxicity. 
Eden: And it seemed to work, 

374
00:18:41,439 --> 00:18:42,905
right? 
Their late toxicity rates were 

375
00:18:42,905 --> 00:18:45,439
low. 
Avery: Yes, they were low. 

376
00:18:45,439 --> 00:18:48,364
But that does not prove the 
spacing helped. 

377
00:18:48,364 --> 00:18:51,649
Remember the Rapid trial. 
Rapid used a twice-daily course 

378
00:18:51,649 --> 00:18:54,147
and had worse cosmesis. 
Eden: Right. 

379
00:18:54,147 --> 00:18:57,229
But Rapid used a higher total 
dose, thirty-eight point five 

380
00:18:57,229 --> 00:19:00,001
gray versus thirty gray. 
The technique and the target 

381
00:19:00,001 --> 00:19:02,521
volumes also differed. 
Eden: So you can't just compare 

382
00:19:02,521 --> 00:19:05,444
Florence and Rapid head-to-head 
and say twice daily is bad and 

383
00:19:05,444 --> 00:19:08,509
every other day is good. 
Avery: Now, the plan review. 

384
00:19:08,509 --> 00:19:11,941
You are sitting at the console, 
and you have the dose-volume 

385
00:19:11,941 --> 00:19:14,125
histogram, the DVH, open on your
screen. 

386
00:19:14,125 --> 00:19:17,869
When you walk her DVH, you do it
in a specific order. 

387
00:19:18,169 --> 00:19:21,895
Eden: Step one, check the PTV 
and CTV coverage. 

388
00:19:21,895 --> 00:19:24,793
Step two, look at the PTV 
maximum. 

389
00:19:24,793 --> 00:19:27,277
Step three, evaluate the 
uninvolved breast. 

390
00:19:27,277 --> 00:19:31,000
Step four, the ipsilateral lung.
Step five, the heart. 

391
00:19:31,000 --> 00:19:33,065
Step six, the contralateral 
lung. 

392
00:19:33,065 --> 00:19:36,629
Eden: And finally, step seven, 
the contralateral breast. 

393
00:19:36,889 --> 00:19:39,407
Avery: Notice what is missing 
from that list. 

394
00:19:39,407 --> 00:19:41,605
The thyroid. 
The Florence protocol sets no 

395
00:19:41,605 --> 00:19:45,687
limit for the thyroid gland, so 
the thyroid is not part of this 

396
00:19:45,687 --> 00:19:48,723
plan review walk. 
Eden: Now let's dive into the 

397
00:19:48,723 --> 00:19:50,956
exact numbers for the Florence 
constraint set. 

398
00:19:50,956 --> 00:19:53,827
First, we look at the 
optimization tier, the ideal 

399
00:19:53,827 --> 00:19:55,849
goals. 
Eden: For coverage, the whole 

400
00:19:55,849 --> 00:19:58,909
PTV must receive at least 
ninety-five percent of the 

401
00:19:58,909 --> 00:20:01,793
prescription dose. 
Avery: For the hotspots, the PTV

402
00:20:01,793 --> 00:20:05,247
maximum must stay at or below 
one hundred and five percent. 

403
00:20:05,247 --> 00:20:08,387
And they also put a floor on the
cold spots. 

404
00:20:08,387 --> 00:20:11,209
The PTV minimum must be at least
twenty-eight gray. 

405
00:20:11,749 --> 00:20:13,873
Eden: Now for the normal 
tissues. 

406
00:20:13,873 --> 00:20:17,767
The uninvolved breast V fifteen 
must stay at or below fifty 

407
00:20:17,767 --> 00:20:20,245
percent. 
V fifteen means the volume of 

408
00:20:20,245 --> 00:20:23,429
the uninvolved breast that 
receives fifteen gray or more. 

409
00:20:24,129 --> 00:20:27,945
Avery: For the ipsilateral lung,
the lung on the side of the 

410
00:20:27,945 --> 00:20:31,121
cancer, the V ten stays at or 
below twenty percent. 

411
00:20:31,121 --> 00:20:34,925
For the heart, the V three stays
at or below ten percent. 

412
00:20:34,925 --> 00:20:39,065
Avery: For the contralateral 
lung on the far side, the V five

413
00:20:39,065 --> 00:20:42,860
stays at or below ten percent 
and finally, the maximum dose 

414
00:20:42,860 --> 00:20:45,961
allowed to reach the 
contralateral breast is one gray

415
00:20:45,961 --> 00:20:48,529
or less. 
Eden: Those are the optimization

416
00:20:48,529 --> 00:20:50,029
limits. 
But at final acceptance, 

417
00:20:50,029 --> 00:20:51,525
Florence allowed a few 
differences. 

418
00:20:51,525 --> 00:20:55,113
For example, they allowed the 
PTV maximum to drift up to one 

419
00:20:55,113 --> 00:20:58,788
hundred and twelve percent. 
Avery: But they allowed no 

420
00:20:58,788 --> 00:21:00,909
differences, no relaxation for 
the uninvolved breast 

421
00:21:00,909 --> 00:21:03,333
constraint. 
That V fifteen at or below fifty

422
00:21:03,333 --> 00:21:06,666
percent was a hard line in the 
sand in both tiers. 

423
00:21:06,666 --> 00:21:09,964
Avery: Remember, this constraint
set belongs to the thirty gray 

424
00:21:09,964 --> 00:21:12,267
in five fraction every other day
schedule. 

425
00:21:12,267 --> 00:21:15,886
It does not belong to a 
three-week schedule, and it does

426
00:21:15,886 --> 00:21:18,189
not belong to a twice-daily 
accelerated schedule. 

427
00:21:18,189 --> 00:21:20,935
Eden: The Astro guideline gives 
one set of starting point 

428
00:21:20,935 --> 00:21:22,579
objectives for both external 
beam schedules. 

429
00:21:22,579 --> 00:21:26,415
It is not a trial set tied to 
one schedule like Florence or B 

430
00:21:26,415 --> 00:21:30,119
thirty-nine. 
Avery: Pause on the third 

431
00:21:30,119 --> 00:21:32,429
workshop question. 
Which structure on this DVH 

432
00:21:32,429 --> 00:21:35,399
matters for partial breast 
treatment but does not matter 

433
00:21:35,399 --> 00:21:37,379
for a standard whole breast 
plan? 

434
00:21:37,379 --> 00:21:39,609
Pause. 
Eden: The uninvolved breast. 

435
00:21:40,549 --> 00:21:43,415
Avery: Sparing the rest of the 
breast tissue is the point of 

436
00:21:43,415 --> 00:21:46,501
partial breast treatment. 
Eden: And this is where you see 

437
00:21:46,501 --> 00:21:49,231
that sparing on the DVH. 
Most Florence plans kept the 

438
00:21:49,231 --> 00:21:52,234
dose to the healthy tissue well 
under the fifty percent limit. 

439
00:21:52,234 --> 00:21:54,964
In fact, the median uninvolved 
breast V fifteen across the 

440
00:21:54,964 --> 00:21:56,329
trial was around thirty-one 
percent. 

441
00:21:57,869 --> 00:22:00,733
Avery: Now brachytherapy. 
If we are evaluating a 

442
00:22:00,733 --> 00:22:04,671
multicatheter implant, we have 
to look at the geometry of the 

443
00:22:04,671 --> 00:22:06,819
catheters. 
This follows the classic Paris 

444
00:22:06,819 --> 00:22:09,318
System. 
The catheters must be placed in 

445
00:22:09,318 --> 00:22:11,722
parallel planes. 
Avery: Those planes should be 

446
00:22:11,722 --> 00:22:14,081
spaced about one to two 
centimeters apart. 

447
00:22:14,081 --> 00:22:17,451
The deep plane of catheters must
run behind the lumpectomy 

448
00:22:17,451 --> 00:22:20,147
cavity, between the bed and the 
chest wall. 

449
00:22:20,147 --> 00:22:23,741
Avery: And the superficial plane
of catheters must be kept at 

450
00:22:23,741 --> 00:22:26,349
least one centimeter away from 
the skin surface. 

451
00:22:26,849 --> 00:22:30,934
Eden: Then you optimize the 
dwell times, how long the source

452
00:22:30,934 --> 00:22:33,531
sits at each position inside 
those catheters. 

453
00:22:33,531 --> 00:22:37,612
You optimize for coverage of the
target, but you also optimize 

454
00:22:37,612 --> 00:22:40,274
for homogeneity. 
Eden: You check the isodose 

455
00:22:40,274 --> 00:22:44,496
lines on the CT scan, scrolling 
slice by slice, looking for 

456
00:22:44,496 --> 00:22:47,943
merged high-dose islands, where 
the radiation from two catheters

457
00:22:47,943 --> 00:22:50,974
pools together. 
Avery: Here's the specific B 

458
00:22:50,974 --> 00:22:52,450
thirty-nine multicatheter 
constraint set. 

459
00:22:52,450 --> 00:22:55,766
This is for thirty-four gray 
delivered in ten twice-daily 

460
00:22:55,766 --> 00:23:00,182
high dose rate or HDR fractions 
of three point four gray each. 

461
00:23:00,182 --> 00:23:03,984
Avery: These fractions must be 
separated by at least six hours,

462
00:23:03,984 --> 00:23:05,709
delivered over five treatment 
days. 

463
00:23:05,909 --> 00:23:08,813
Eden: For coverage, ninety 
percent of the prescription dose

464
00:23:08,813 --> 00:23:12,355
must cover at least ninety 
percent of the PTV eval volume. 

465
00:23:12,355 --> 00:23:16,420
Eden: The V one fifty is at most
seventy cc, the V two hundred is

466
00:23:16,420 --> 00:23:19,672
at most twenty cc, and the dose 
homogeneity index, which is one 

467
00:23:19,672 --> 00:23:23,189
minus V one fifty divided by V 
one hundred, must be at least 

468
00:23:23,189 --> 00:23:28,672
zero point seven five. 
Avery: V one fifty is the volume

469
00:23:28,672 --> 00:23:31,631
of breast tissue that receives 
at least one hundred and fifty 

470
00:23:31,631 --> 00:23:32,976
percent of the prescription 
dose. 

471
00:23:32,976 --> 00:23:36,194
V two hundred is the volume that
receives at least twice the 

472
00:23:36,194 --> 00:23:38,140
prescription dose. 
Avery: These metrics measure the

473
00:23:38,140 --> 00:23:42,014
high-dose tissue in an implant. 
Eden: We also look at the skin. 

474
00:23:42,014 --> 00:23:44,849
The skin dose should not exceed 
the prescription dose. 

475
00:23:44,849 --> 00:23:47,991
And ideally under sixty percent 
of the whole breast reference 

476
00:23:47,991 --> 00:23:50,189
volume should receive half the 
prescription dose. 

477
00:23:50,649 --> 00:23:54,018
Avery: The European trial asked 
for more coverage and more skin 

478
00:23:54,018 --> 00:23:55,944
sparing. 
Avery: They demanded the full 

479
00:23:55,944 --> 00:23:58,860
one hundred percent prescription
dose cover at least ninety 

480
00:23:58,860 --> 00:24:02,743
percent of the target, and they 
wanted the skin dose kept under 

481
00:24:02,743 --> 00:24:05,327
seventy percent. 
You must quote each number with 

482
00:24:05,327 --> 00:24:07,965
its owner. 
Avery: Do not build one plan 

483
00:24:07,965 --> 00:24:10,618
using B thirty-nine coverage 
limits and European skin 

484
00:24:10,618 --> 00:24:13,789
constraints. 
Eden: Now consider the single 

485
00:24:13,789 --> 00:24:17,085
entry device, a balloon or a 
strut applicator. 

486
00:24:17,085 --> 00:24:19,557
The Astro guideline 
conditionally recommends single 

487
00:24:19,557 --> 00:24:22,279
entry brachytherapy. 
Eden: No randomized trial has 

488
00:24:22,279 --> 00:24:25,690
compared these single entry 
devices alone with whole breast 

489
00:24:25,690 --> 00:24:27,793
radiation. 
Avery: The B thirty-nine 

490
00:24:27,793 --> 00:24:31,159
protocol judged a placed single 
entry device on four checks, and

491
00:24:31,159 --> 00:24:34,941
all four of them are essential. 
Eden: The first check is 

492
00:24:34,941 --> 00:24:37,111
conformance. 
You get pockets of trapped air 

493
00:24:37,111 --> 00:24:38,971
or trapped fluid around the 
balloon. 

494
00:24:38,971 --> 00:24:42,381
B thirty-nine requires you to 
subtract the share of the PTV 

495
00:24:42,381 --> 00:24:45,171
eval that is displaced by that 
air or fluid. 

496
00:24:45,171 --> 00:24:48,603
Eden: After subtracting it, at 
least ninety percent of the PTV 

497
00:24:48,603 --> 00:24:51,409
eval must still receive ninety 
percent of the dose. 

498
00:24:51,689 --> 00:24:55,418
Avery: If a pocket of air 
displaces five percent of your 

499
00:24:55,418 --> 00:24:57,791
PTV eval, you subtract that five
percent. 

500
00:24:57,791 --> 00:25:00,842
Now, at least ninety-five 
percent of your original PTV 

501
00:25:00,842 --> 00:25:03,551
eval must meet the ninety 
percent dose coverage 

502
00:25:03,551 --> 00:25:05,924
requirement. 
Eden: The second check is 

503
00:25:05,924 --> 00:25:08,437
symmetry. 
For a single lumen balloon, the 

504
00:25:08,437 --> 00:25:11,667
CT must confirm that the 
expanded balloon stays within 

505
00:25:11,667 --> 00:25:13,815
two millimeters of its 
manufacturer's expected 

506
00:25:13,815 --> 00:25:15,493
dimensions. 
Eden: Multi-lumen strut devices 

507
00:25:15,493 --> 00:25:18,788
don't have to be perfectly 
symmetric, but they are judged 

508
00:25:18,788 --> 00:25:21,749
by whether they still meet the 
final dose goals. 

509
00:25:22,329 --> 00:25:24,562
Avery: The third check is skin 
distance. 

510
00:25:24,562 --> 00:25:27,749
The surface of the balloon must 
sit ideally seven millimeters 

511
00:25:27,749 --> 00:25:30,929
away from the skin and at least 
five millimeters away. 

512
00:25:31,109 --> 00:25:33,368
Eden: The fourth check is the 
normal breast dose. 

513
00:25:33,368 --> 00:25:37,133
For a balloon, the V one fifty 
can be at most fifty cc and the 

514
00:25:37,133 --> 00:25:41,551
V two hundred at most ten cc. 
Avery: The skin maximum is where

515
00:25:41,551 --> 00:25:43,088
the different rule sets part 
ways. 

516
00:25:43,088 --> 00:25:46,179
Avery: B thirty-nine allowed the
skin to receive up to one 

517
00:25:46,179 --> 00:25:48,708
hundred and forty-five percent 
of the prescription dose, as 

518
00:25:48,708 --> 00:25:52,069
long as the device sat five to 
seven millimeters from the skin.

519
00:25:52,369 --> 00:25:55,240
Eden: The current Astro 
guideline asks for the maximum 

520
00:25:55,240 --> 00:25:58,430
skin dose to be under one 
hundred and twenty-five percent 

521
00:25:58,430 --> 00:26:01,934
as merely acceptable and pushes 
for under one hundred percent as

522
00:26:01,934 --> 00:26:04,664
the ideal goal. 
Eden: The guideline calls this 

523
00:26:04,664 --> 00:26:07,859
out, stating its recommendation 
is stricter than what B 

524
00:26:07,859 --> 00:26:11,459
thirty-nine allowed. 
Avery: Astro gives two reasons. 

525
00:26:11,459 --> 00:26:14,861
First, technology evolved. 
Modern multi-lumen devices reach

526
00:26:14,861 --> 00:26:18,263
lower skin doses. 
Second, clinical reality caught 

527
00:26:18,263 --> 00:26:20,689
up. 
Skin toxicity correlates with 

528
00:26:20,689 --> 00:26:25,149
that maximum skin dose. 
Eden: So we pass or fail a 

529
00:26:25,149 --> 00:26:27,849
balloon plan's skin maximum on 
the modern guideline's one 

530
00:26:27,849 --> 00:26:29,349
hundred and twenty-five percent 
line. 

531
00:26:29,349 --> 00:26:32,733
Eden: However, we still show the
one hundred and forty-five 

532
00:26:32,733 --> 00:26:35,437
percent limit on our 
documentation as the historical 

533
00:26:35,437 --> 00:26:39,444
B thirty-nine trial allowance. 
Avery: Pause on the fourth 

534
00:26:39,444 --> 00:26:42,921
workshop question. 
Why can't you check the V one 

535
00:26:42,921 --> 00:26:45,623
fifty on our patient's external 
beam plan? 

536
00:26:45,623 --> 00:26:47,945
Pause. 
Eden: Because if you have built 

537
00:26:47,945 --> 00:26:50,753
an acceptable external beam 
plan, no point on it gets one 

538
00:26:50,753 --> 00:26:52,538
hundred and fifty percent of the
dose. 

539
00:26:52,538 --> 00:26:55,109
Eden: The Florence constraints 
held the external beam PTV 

540
00:26:55,109 --> 00:26:57,959
maximum to one hundred and five 
percent when optimizing and 

541
00:26:57,959 --> 00:27:00,809
capped it at one hundred and 
twelve percent at final 

542
00:27:00,809 --> 00:27:02,804
acceptance. 
V one fifty is an implant 

543
00:27:02,804 --> 00:27:05,534
metric. 
Avery: Give me the sixty-second 

544
00:27:05,534 --> 00:27:07,724
board answer. 
Describe partial breast target 

545
00:27:07,724 --> 00:27:11,009
construction and the key 
brachytherapy dose goals for one

546
00:27:11,009 --> 00:27:12,829
protocol. 
Pause and draft it. 

547
00:27:13,229 --> 00:27:14,949
Eden: I would use NSABP B 
thirty-nine. 

548
00:27:14,949 --> 00:27:18,502
Eden: For 3D conformal external 
beam, the CTV is the lumpectomy 

549
00:27:18,502 --> 00:27:21,406
cavity plus fifteen millimeters,
kept five millimeters from the 

550
00:27:21,406 --> 00:27:24,626
skin and limited by the 
posterior breast tissue, and the

551
00:27:24,626 --> 00:27:27,202
PTV adds ten millimeters for 
setup and breathing. 

552
00:27:27,202 --> 00:27:29,513
Eden: Limits are checked on the 
cropped PTV eval. 

553
00:27:29,513 --> 00:27:31,949
Eden: Brachytherapy is 
thirty-four gray in ten 

554
00:27:31,949 --> 00:27:35,429
twice-daily fractions, at least 
six hours apart, with no setup 

555
00:27:35,429 --> 00:27:38,561
margin: the cavity plus fifteen 
millimeters for a multicatheter 

556
00:27:38,561 --> 00:27:42,040
implant, or ten millimeters from
the device surface for a 

557
00:27:42,040 --> 00:27:44,348
single-entry device. 
Eden: Ninety percent of the dose

558
00:27:44,348 --> 00:27:47,034
should cover at least ninety 
percent of the PTV eval. 

559
00:27:47,034 --> 00:27:49,554
Eden: For multicatheter 
implants, V one fifty at most 

560
00:27:49,554 --> 00:27:52,907
seventy cc, V two hundred at 
most twenty cc, and a dose 

561
00:27:52,907 --> 00:27:55,418
homogeneity index of at least 
zero point seven five. 

562
00:27:55,418 --> 00:27:57,903
Eden: Single-entry devices are 
conditionally recommended and 

563
00:27:57,903 --> 00:28:01,096
need the four device checks, 
including at least five 

564
00:28:01,096 --> 00:28:04,450
millimeters to the skin. 
Eden: I judge the skin maximum 

565
00:28:04,450 --> 00:28:07,349
on the current guideline's under
one hundred twenty-five percent.

566
00:28:08,689 --> 00:28:12,676
Avery: Before we treat the 
patient, we have to talk about 

567
00:28:12,676 --> 00:28:16,296
quality assurance, or QA. 
For a brachytherapy plan, QA is 

568
00:28:16,296 --> 00:28:18,830
a multi-step process. 
You check the catheter 

569
00:28:18,830 --> 00:28:20,640
reconstruction against the CT 
scan. 

570
00:28:20,640 --> 00:28:23,169
Avery: You have the plan 
independently checked. 

571
00:28:23,689 --> 00:28:27,066
Eden: And before each of those 
ten fractions, you verify the 

572
00:28:27,066 --> 00:28:30,435
catheter or device position. 
Right before you hit go, you run

573
00:28:30,435 --> 00:28:32,577
a dummy check cable through the 
tubes. 

574
00:28:32,577 --> 00:28:35,797
Eden: And after the treatment 
finishes, you confirm that the 

575
00:28:35,797 --> 00:28:38,369
source has fully retracted back 
into the safe. 

576
00:28:38,649 --> 00:28:42,229
Avery: For her external beam 
plan, the QA is different. 

577
00:28:42,229 --> 00:28:44,377
It relies on patient-specific 
IMRT QA. 

578
00:28:44,377 --> 00:28:48,304
We have to prove the machine can
deliver what the computer 

579
00:28:48,304 --> 00:28:50,089
modeled. 
This is institutional practice. 

580
00:28:50,749 --> 00:28:54,434
Eden: Let's run the drill. 
Plan A is her first external 

581
00:28:54,434 --> 00:28:56,444
beam pass. 
You walk the DVH. 

582
00:28:56,444 --> 00:28:58,789
The PTV coverage meets the 
Florence set. 

583
00:28:58,789 --> 00:29:02,466
However, you look down the list 
at the uninvolved breast V 

584
00:29:02,466 --> 00:29:05,014
fifteen. 
Eden: It is over the fifty 

585
00:29:05,014 --> 00:29:07,225
percent limit. 
Remember that fifty percent 

586
00:29:07,225 --> 00:29:10,905
limit holds in both of the 
Florence tiers, optimization and

587
00:29:10,905 --> 00:29:13,481
acceptance. 
Do you accept this plan, revise 

588
00:29:13,481 --> 00:29:17,904
it, or escalate to whole breast?
Avery: You cannot accept it. 

589
00:29:17,904 --> 00:29:20,699
You must revise. 
You send it back to the 

590
00:29:20,699 --> 00:29:24,419
dosimetrist and ask them to try 
new beam angles or run a 

591
00:29:24,419 --> 00:29:25,969
re-optimization of the IMRT 
parameters. 

592
00:29:26,629 --> 00:29:30,485
Eden: Plan A two comes back. 
This time, the V fifteen is 

593
00:29:30,485 --> 00:29:33,695
under the fifty percent limit, 
and the target coverage remains 

594
00:29:33,695 --> 00:29:35,621
unchanged. 
You accept plan A two. 

595
00:29:35,621 --> 00:29:39,401
Eden: Here is the replan request
you sent, short enough for a 

596
00:29:39,401 --> 00:29:42,551
quick text to your dosimetrist. 
Uninvolved breast V fifteen is 

597
00:29:42,551 --> 00:29:46,645
over fifty percent on plan A. 
Can you try new beam angles and 

598
00:29:46,645 --> 00:29:50,195
keep PTV coverage where it is? 
Avery: What if the dosimetrist 

599
00:29:50,195 --> 00:29:52,187
came back and said they can't do
it? 

600
00:29:52,187 --> 00:29:54,677
If revision fails because the 
target volume fills a large 

601
00:29:54,677 --> 00:29:56,669
share of her breast, what do you
do? 

602
00:29:56,889 --> 00:30:00,369
Eden: In that scenario, whole 
breast radiation may be the 

603
00:30:00,369 --> 00:30:02,106
safer, more appropriate clinical
plan. 

604
00:30:02,106 --> 00:30:04,188
That is a planning judgment 
call. 

605
00:30:04,188 --> 00:30:07,887
Eden: B thirty-nine said that 
when the PTV was more than 

606
00:30:07,887 --> 00:30:11,247
twenty to twenty-five percent of
the reference breast volume, its

607
00:30:11,247 --> 00:30:14,607
limits were likely out of reach 
with 3D conformal treatment. 

608
00:30:14,607 --> 00:30:18,167
Eden: The Florence trial, using 
IMRT, treated ratios up to 

609
00:30:18,167 --> 00:30:20,659
thirty-eight percent. 
How to fractionate that whole 

610
00:30:20,659 --> 00:30:22,789
breast radiation is its own 
topic. 

611
00:30:23,029 --> 00:30:26,475
Avery: Let's look at plan B. 
This is the brachytherapy 

612
00:30:26,475 --> 00:30:28,883
balloon alternative on the same 
CT scan. 

613
00:30:28,883 --> 00:30:32,667
The edge of the device sits 
under five millimeters from the 

614
00:30:32,667 --> 00:30:35,419
skin surface. 
That is below the B thirty-nine 

615
00:30:35,419 --> 00:30:37,929
minimum. 
Avery: And the skin maximum is 

616
00:30:37,929 --> 00:30:41,529
over the Astro guideline's limit
of one hundred and twenty-five 

617
00:30:41,529 --> 00:30:44,049
percent. 
It fails both the distance check

618
00:30:44,049 --> 00:30:46,929
and the dose check. 
Accept, revise, or escalate? 

619
00:30:47,169 --> 00:30:51,009
Eden: You must escalate, which 
in this context means changing 

620
00:30:51,009 --> 00:30:54,081
the treatment technique. 
You must switch to a 

621
00:30:54,081 --> 00:30:56,001
multicatheter brachytherapy 
implant, or abandon 

622
00:30:56,001 --> 00:30:59,069
brachytherapy and move to 
external beam partial breast. 

623
00:30:59,309 --> 00:31:01,045
Avery: The fix is a different 
technique. 

624
00:31:01,045 --> 00:31:03,773
The fix is not lowering the 
prescription dose until the skin

625
00:31:03,773 --> 00:31:06,644
is safe. 
Eden: Let's consider variant C. 

626
00:31:06,644 --> 00:31:08,439
The patient arrives for 
simulation. 

627
00:31:08,439 --> 00:31:12,029
You read the op note. 
She had an oncoplastic closure. 

628
00:31:12,029 --> 00:31:15,257
There are no surgical clips. 
The seroma has collapsed. 

629
00:31:15,257 --> 00:31:18,884
What do you do? 
Avery: Escalate to whole breast 

630
00:31:18,884 --> 00:31:20,869
radiation. 
You cannot map the target. 

631
00:31:20,869 --> 00:31:23,839
Now, who communicates what? 
Plan A's revision was a 

632
00:31:23,839 --> 00:31:26,479
technical issue. 
That goes straight back to the 

633
00:31:26,479 --> 00:31:28,459
dosimetrist as a quick replan 
text. 

634
00:31:28,459 --> 00:31:31,869
Avery: But plan B, failing the 
balloon constraints, and variant

635
00:31:31,869 --> 00:31:34,929
C, failing to find the cavity, 
are physician decisions. 

636
00:31:34,929 --> 00:31:38,329
They must be discussed with the 
patient, explaining why the 

637
00:31:38,329 --> 00:31:42,524
initial strategy has to change. 
Eden: Now three planning traps. 

638
00:31:42,524 --> 00:31:44,813
Trap one. 
Avery: Borrowing a constraint 

639
00:31:44,813 --> 00:31:47,124
set across a technique or a 
schedule. 

640
00:31:47,124 --> 00:31:50,963
Avery: For example, evaluating a
V one fifty metric on an 

641
00:31:50,963 --> 00:31:54,453
external beam plan, or applying 
the B thirty-nine twice daily 

642
00:31:54,453 --> 00:31:57,243
external beam constraint set to 
a thirty-in-five plan. 

643
00:31:57,243 --> 00:32:00,955
Avery: A trial's constraint set 
belongs to its own delivery 

644
00:32:00,955 --> 00:32:03,181
technique and its own 
fractionation schedule. 

645
00:32:03,181 --> 00:32:07,141
Avery: Trap two, drawing the 
tumor bed from the external skin

646
00:32:07,141 --> 00:32:10,376
scar, or offering partial breast
treatment when an oncoplastic 

647
00:32:10,376 --> 00:32:13,607
surgical bed cannot be 
confidently localized on the CT 

648
00:32:13,607 --> 00:32:16,001
scan. 
Avery: Trap three, judging your 

649
00:32:16,001 --> 00:32:19,664
coverage on a structure other 
than the protocol's evaluation 

650
00:32:19,664 --> 00:32:22,915
structure, like judging B 
thirty-nine coverage on the 

651
00:32:22,915 --> 00:32:26,975
uncropped PTV instead of the 
cropped PTV eval, or skipping 

652
00:32:26,975 --> 00:32:29,817
daily image guidance when 
delivering five-fraction partial

653
00:32:29,817 --> 00:32:33,099
breast treatment. 
Eden: Let's finish with Board 

654
00:32:33,099 --> 00:32:34,771
Blitz. 
Two quick cases. 

655
00:32:34,771 --> 00:32:38,527
Case one, you are evaluating a 
multicatheter brachytherapy plan

656
00:32:38,527 --> 00:32:42,697
after open cavity surgery. 
You are planning by the European

657
00:32:42,697 --> 00:32:44,849
rule. 
Eden: The surgical pathology 

658
00:32:44,849 --> 00:32:48,313
report shows an eight-millimeter
posterior margin of healthy 

659
00:32:48,313 --> 00:32:51,344
tissue. 
What CTV margin do you add 

660
00:32:51,344 --> 00:32:53,509
posteriorly to the cavity? 
Pause. 

661
00:32:55,149 --> 00:32:57,718
Avery: Twelve millimeters. 
So twenty minus the 

662
00:32:57,718 --> 00:33:00,283
eight-millimeter surgical margin
leaves a twelve-millimeter CTV 

663
00:33:00,283 --> 00:33:02,113
expansion. 
B thirty-nine's uniform fifteen 

664
00:33:02,113 --> 00:33:04,309
millimeters belongs to a 
different protocol. 

665
00:33:04,929 --> 00:33:08,581
Eden: Case two, you are 
reviewing the planning CT for a 

666
00:33:08,581 --> 00:33:11,561
single entry balloon device. 
You notice pockets of trapped 

667
00:33:11,561 --> 00:33:13,547
air and fluid around the 
balloon. 

668
00:33:13,547 --> 00:33:17,519
This air and fluid displaces 
about a fifth of the PTV eval 

669
00:33:17,519 --> 00:33:19,674
volume. 
Eden: Can you proceed and treat 

670
00:33:19,674 --> 00:33:21,189
the device as placed? 
Pause. 

671
00:33:21,589 --> 00:33:23,551
Avery: No. 
The B thirty-nine conformance 

672
00:33:23,551 --> 00:33:26,821
rule states that if the 
displacement is above a tenth, 

673
00:33:26,821 --> 00:33:28,782
acceptable dosimetric coverage 
is not possible. 

674
00:33:28,782 --> 00:33:32,324
Avery: You must either fix the 
device and eliminate the air, or

675
00:33:32,324 --> 00:33:34,389
you must change the treatment 
technique entirely. 

676
00:33:34,709 --> 00:33:37,648
Eden: Finally, if she asks you 
in the clinic why her external 

677
00:33:37,648 --> 00:33:41,064
beam plan needed a second pass, 
why plan A became plan A two, a 

678
00:33:41,064 --> 00:33:43,360
plain answer is this. 
Eden: Your first plan covered 

679
00:33:43,360 --> 00:33:46,528
the area around your lumpectomy 
very well, but it gave more dose

680
00:33:46,528 --> 00:33:49,163
than we want to the rest of your
healthy breast. 

681
00:33:49,163 --> 00:33:52,614
Eden: We went back and changed 
the beam angles so that more of 

682
00:33:52,614 --> 00:33:55,529
your breast is spared, while the
target area we are treating 

683
00:33:55,529 --> 00:33:57,649
remains the same. 
Before each treatment, we take 

684
00:33:57,649 --> 00:33:59,769
images to check that we are 
lined up. 

685
00:34:00,409 --> 00:34:03,954
Avery: It is honest, it is 
accurate, and it strips away the

686
00:34:03,954 --> 00:34:06,707
jargon. 
Eden: So we look back at that 

687
00:34:06,707 --> 00:34:09,647
initial seroma ringed by clips. 
Her final accepted plan is 

688
00:34:09,647 --> 00:34:12,583
thirty gray in five fractions 
delivered every other day with 

689
00:34:12,583 --> 00:34:14,047
IMRT. 
The target definitions were 

690
00:34:14,047 --> 00:34:16,645
built on Florence's rules. 
Eden: The dose was checked 

691
00:34:16,645 --> 00:34:19,485
against the Florence constraint 
set, and she will be treated 

692
00:34:19,485 --> 00:34:22,609
with daily image guidance. 
Plan A two is accepted, and her 

693
00:34:22,609 --> 00:34:25,969
partial breast plan is built. 
Avery: In the next episode, 

694
00:34:25,969 --> 00:34:28,377
Episode fifteen, Regional nodal 
irradiation after breast 

695
00:34:28,377 --> 00:34:31,811
conservation, we ask whether her
lymph nodes need treatment too, 

696
00:34:31,811 --> 00:34:33,869
and who does need nodal 
radiation. 

697
00:34:33,869 --> 00:34:36,759
Avery: Get show notes and 
complete practice oral boards at

698
00:34:36,759 --> 00:34:40,217
Rad Onc Smart Learn dot com, and
subscribe for our next episode. 

699
00:34:40,217 --> 00:34:41,369
Thanks for tuning in!